Skip to main content

Table 1 Summary of the different observational and experimental settings in which different passive samplers were compared

From: Passive dust collectors for assessing airborne microbial material

 

Notation

Occupancy/input

Collection notes

Height above ground (m)

Samplers employed

USA homes

House 1

Single

4 weeks

0.3, 1.4a

PD(2), T(2), EDC1(2), EDC2(2)

 

House 2

Couple

4 weeks

1, 2.6

PD(2), T(2), EDC1(2), EDC2(2)

 

House 3

Family of five plus three dogs

4 weeks

0.5, 1.5

PD(2), T(2), EDC1(2), EDC2(2)

Finland buildings

House 1

Family of three

5 weeks

2.1a

PD(2), T(2), EDC3(2)

 

House 2

Family of four plus dog

4 weeks

1.7

PD(2), T(2), EDC3(2)

 

House 3

Couple plus two dogs

4 weeks

1.2

PD(2), T(2), EDC3(2)

 

House 4

Family of three plus three dogs

4 weeks

2.0

PD(2), T(2), EDC3(2)

 

House 5

Weekend residence

4 weeks

2.3

PD(2), T(2), EDC3(2)

 

Office 1

Single

4 weeks

2.1

PD(2), T(2), EDC3(2)

 

Office 2

Triple

4 weeks

2.1

PD(2), T(2), EDC3(2)

 

Labspace

Daily use

4 weeks

2.1

PD(2), T(2), EDC3(2)

Chamber

Ch1

Dust mix 1b

3.17 gc

n/a

PD, T, EDC1, EDC2

 

Ch2

Dust mix 1

2.59 g

n/a

PD, T, EDC1, EDC2

 

Ch3

Dust mix 2

2.66 g

n/a

PD, T, EDC1, EDC2

 

Ch4

Dust mix 2

1.78 g

n/a

PD, T, EDC1, EDC2

 

Ch5

Dust mix 3

2.80 g

n/a

PD, T, EDC1, EDC2

 

Ch6

Dust mix 3

3.13 g

n/a

PD, T, EDC1, EDC2

  1. EDC1,2,3 refer to different sampler materials
  2. PD petri dish, T TefTex, EDC electrostatic dustfall collector
  3. aIn the USA homes, four samplers were placed at two heights, for a total of eight samplers per home. In the Finnish buildings, duplicates for each of three samplers were employed at a single height, for a total of six samples per building
  4. bDust from different vacuum bags was combined into three different “dust mixes”
  5. cRefers to the mass of dust input into the experimental chamber